mirage

Indoor bacterial load and its correlation to physical indoor air quality parameters in public primary schools

DSpace Repository

Show simple item record

dc.contributor.author Zewudu Andualem*, Zemichael Gizaw, Laekemariam Bogale and Henok Dagne
dc.date.accessioned 2019-06-12T08:13:44Z
dc.date.available 2019-06-12T08:13:44Z
dc.date.issued 2019-04-23
dc.identifier.uri http://hdl.handle.net/123456789/2213
dc.description.abstract Background: Poor indoor air quality is a great problem in schools due to a high number of students per classroom, insufficient outside air supply, poor construction and maintenance of school buildings. Bacteria in the indoor air environment pose a serious health problem. Determination of bacterial load in the indoor environment is necessary to estimate the health hazard and to create standards for indoor air quality control. This is especially important in such densely populated facilities like schools. Methods: Institutional based cross-sectional study was conducted among 51 randomly selected classrooms of eight public primary schools from March 29–April 26, 2018. To determine the bacterial load passive air sampling settle plate method was used by exposing a Petri dish of blood agar media for an hour. The Pearson correlation matrix was employed to assess the correlation between bacterial load and physical parameters. Results: The grand total mean bacterial load was 2826.35 CFU/m3 in the morning and 4514.63 CFU/m3 in the afternoon. The lowest and highest mean bacterial load was recorded at school 3 (450.67 CFU/m3) and school 5 (7740.57 CFU/m3) in the morning and afternoon, respectively. In the morning relative humidity (r = − 0.7034), PM2.5 (r = 0.5723) and PM10 (r = 0.6856); in the afternoon temperature (r = 0.3838), relative humidity (r = − 0.4014) were correlated with indoor bacterial load. Staphylococcus aureus, Coagulase-negative Staphylococcus species and Bacillus species were among isolated bacteria. Conclusions: High bacterial load was found in public primary schools in the Gondar city as compared to different indoor air biological standards. Temperature, relative humidity and particulate matter concentration (PM2.5 and PM10) were associated with the indoor bacterial load. Staphylococcus aureus, Coagulase-negative Staphylococcus species and Bacillus species were among isolated bacterial species. Attention should be given to control those physical factors which favour the growth and multiplication of bacteria in the indoor environment of classrooms to safeguard the health of students and teachers in school. en_US
dc.language.iso en en_US
dc.subject Keywords: Bacterial load, Classrooms, Correlation, Indoor air, Settle plate method en_US
dc.title Indoor bacterial load and its correlation to physical indoor air quality parameters in public primary schools en_US
dc.type Article en_US


Files in this item

This item appears in the following Collection(s)

Show simple item record

Search in the Repository


Advanced Search

Browse

My Account